P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors

Product Details
Customization: Available
Color: Black
Material: ABS
Still deciding? Get samples of US$ 20/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (24)
  • P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
  • P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
  • P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
  • P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
  • P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
  • P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
P-B-2
Service Life
5 Years
Case Material
ABS
Match Respirator
Hg-700/800/800d/911
Transport Package
Cartons, Standard Packaging
Specification
1pc/pack
Trademark
Haigu
Origin
China
HS Code
8421399090
Production Capacity
100, 000PCS/Month

Product Description

Product Description
Haigu anti-virus filters are produced, packaged, color-coded, and inspected in accordance with relevant national standards, and further optimize the internal structure design and anti-virus effect, with performance far exceeding similar products. The manufacturing process is advanced, and the filter element adopts a multi-layer filter structure, and the actual protection time meets the national standard requirements.

The core selling points of the first-level filter box:
Three-layer structure, efficient evolution of poison gas
Larger capacity, exceeding national standard protection time
ABS shell, light weight, pressure resistance and corrosion resistance
Highly efficient sealing, long-term effectiveness of the medicine

1.Cartridge/Canister Filter Element Table 
Model Color Protective Medium
A Type    Protection against organic gases or vapors; benzene, aniline, carbon tetrachloride, nitrobenzene, chloropicrin
B Type   Protection against inorganic gases or vapors; hydrogen chloride, hydrocyanic acid, chlorine
E Type   Protection against sulfur dioxide and other acidic gases or vapors 
K Type    Protection against Ammonia and its organic derivatives 
CO Type   Protection against carbon monoxide gas
Hg Type   Protection against mercury vapor
H2S Type   Protection against hydrogen sulfide gas
Combination Type D-A/B/E/K/H2S   Protection against organic, non-electrode, acidic gas or steam, ammonia and ammonia derivatives, hydrogen sulfide gas
 
 
 
 
Combination Type D-A/B/E/K/CO/H2S   Protection against organic, non-electrode, acidic gas or steam, ammonia and ammonia derivatives, carbon monoxide, hydrogen sulfide gas
 
 
 
 
 
2.Combination Smoke and Gas Filter Cartridge/Canister Table 
Model Color Protective Medium
A Type    Protection against organic gases or vapors; benzene, aniline, carbon tetrachloride, nitrobenzene, chloropicrin,and smoke
 
B Type   Protection against inorganic gases or vapors; hydrogen chloride, hydrocyanic acid, chlorine,and smoke
 
E Type   Protection against sulfur dioxide and other acidic gases or vapors,and smoke
 
K Type    Protection against Ammonia and its organic derivatives,and smoke
 
CO Type   Protection against carbon monoxide gas and smoke
 
H2S Type   Protection against hydrogen sulfide gasand smoke
 
Combination Type Z-A/B/E/K/H2S   Protection against organic, non-electrode, acidic gas or steam, ammonia and ammonia derivatives, hydrogen sulfide gas,and smoke
 
 
 
 
 

Q&A:
1.Q: How long is the shelf life of the filter box?
   A: The filter should be stored in a dry,clean,pollution-free,direct sunlight free and airy warehouse,strictly against humidity and
        high temperature.The storage period of the filter that meets the above storage conditions is 5 years,subject to the
        production date.Please use it before the storage period.

2.Q: How to judge whether the filter cartridge is effective or not?
   A: The use time of the filter is effected by many factors,such as the concentration of pollutants in the specific environment air humidity,user
         respiratory rate and so on.After wearing it correctly,we suggest that you immediately establish a replacement schedule and replace
         the filter box regularly,when you have smelled harmful smell or feel unwell, it may indicate that the filter cartridge has been saturated,please
        leave the working environment immediately and go to a safe place to replace the filter box.

3.Q: Can filter cotton washable ?
   A: No,because the adsorption principle of the filter element is electrostatic adsorption,and permanent static electricity will rush into it.fit is
        washed,the product structure layer will be damaged,and the protection effect will be greatly reduced,so it cannot be washed.

4.Q: How to determine when to change the filter cotton?
   A:The filter cotton can normally be used for 7 days.When the surface of the filter cotton is very dirty and there is dust at the observation
       port,the respiratory resistance is seriously blocked,which indicates that the structural layer is damaged and the protection effect is reduced.
       At this time,even if the dust concentration is small,it should be replaced immediately.

5.Q: The activated carbon in the filter box is invalid after use.Can it be replaced by itself?
   A : No,it is strictly forbidden to assemble,disassemble and replace the gas mask and its filter parts by individuals,so as to ensure the ant-
        virus effect and life safety.At this time,just need to replace the new cartridges.

Detailed Photos
P-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
 
Product Parameters
 
Model No.: P-B-2
Size:  D9.5*10.2CM
Case Material: ABS
Specification: 1 pc/pack
 
 
Packaging & Shipping
P-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or VaporsP-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
P-B-2 Canister for Class 2 Protection Against Inorganic Gases or Vapors
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier